Technical characteristics METALOTERM® ME
|
Application
|
|
|
|
|
|
Chimney/Flue system/Connecting flue
|
|
Operating mode
|
|
|
|
|
|
Dry/wet
|
|
Pressure
|
|
|
|
|
|
Negative/positive pressure
|
|
Max. working pressure
|
|
|
|
|
|
200 Pa
|
|
Operating temperature
|
|
|
|
|
|
450 °C negative pressure (EN 1856-2)
400 °C negative pressure (EN 1856-1)
200 °C positive pressure
|
|
Max. temperature allowed
|
|
|
|
|
|
1000°C (EN 1856-2) (max. 30 min.)
400 °C negative pressure (EN 1856-1)
200 °C positive pressure
|
|
Material
|
|
|
|
|
|
AISI 316L/EN 1.4404
|
|
Thickness
|
|
|
|
|
|
minimal 0.5 mm
|
|
Sealant
|
|
|
|
|
|
Elastomer
|
|
Fuel type
|
|
|
|
|
|
Wood/coal/oil/natural gas/calor gas/propane gas
|
CE:
1856-1:
T200-P1-W-V2-L50050-O30
T400-N1-W-V2-L50050-O70
1856-2:
T450-N1-D-V2-L50050-G400
T450-N1-D-V2-L50050-G
T200-P1-W-V2-L50050-O30
T200-P1-W-V2-L50050-O
T400-N1-W-V2-L50050-O100
The clearance to combustible materials, as indicated in the CE-designation, applies to flues with a nominal diameter up to and including 300 mm. Regarding flues with a larger nominal diameter, the clearance must be multiplied b a factor: ø350 - ø450 x 1.5, ø500 - ø600 x 2, > ø700 x 4.
Applications METALOTERM® ME
- Shaft liner in renovation projects
- Air inlet & ventilation systems
- Flue system for condensing heaters and boilers
- Chimney renovation
Advantages METALOTERM® ME
- Stress free thermal expansion
- Can be connected to METALOTERM® MF
- High quality stainless steel system
- High temperature silicone sealing ring
- Universal application
- Fully welded system with sealing ring
- Light weight system
|
Diameter
|
mm
|
80
|
100
|
113
|
130
|
150
|
180
|
200
|
250
|
300
|
350
|
400
|
|
Cross section
|
cm2
|
50
|
79
|
100
|
133
|
177
|
254
|
314
|
491
|
707
|
962
|
1256
|
|
Weight
|
±kg/m
|
1.5
|
1.5
|
2
|
2
|
2.5
|
3
|
3
|
4
|
4.5
|
5.5
|
6
|
|